Languages:
Quality First, Service Excellent, Global Trust!
 
   HOME              COMPANY              PRODUCT                SERVICE               NEWS               OEM               CONTACT US
 
  Health Care
  Color Doppler
  B&W Ultrasound Scanner
  Patient Monitoring
  Fetal Monitoring
  ECG Machine
  Diagnostic Cardiology
  Neurology
  Anesthesia Machine
  Ventilator
  Operation Table
  Operation Light
  Operation Microscope
  Electrosurgical Unit
  Infusion/Syringe Pump
  Endoscope
  Infant Care System
  Clinical Laboratory (In-Vitro)
  Ophthalmic Equipment
  Veterinary
  Home Tools
  Home Decor
  Automotive
 
Vet
Product Name: Vet Infusion Pump
Model: IP-50V
P/N/: 150116
Product's Video: No Video
Inquiry:


Infusion Pump

SKU:100117

Features:

1. Audible and visual alarm for occlusion, empty, low battery, end of infusion, door open, wrong setting etc, which gain patents

2. HD LCD Display, high capacity words, friendly user interface, dynamically display working status

3. Compatible with any brand of infusion sets after correct calibration

4. Preset Solution Volume to greatly reduce the workload of nurses

5. Work mode: ml/h and drop/min can switch freely 

6. Three levels of occlusion: high, middle and low

7. Purge function

8. KVO: KVO (keep-vein-open) automatically opens as infusion is completed.

9. Power Source: AC100-240V, 50/60Hz; Internal Battery

10. Automatically record the settings of last infusion can be available per customers request

11. Language: English, Poland, Latvian, Russian etc


Specification:

1. Infusion Rate 0.1ml/h---1200ml/h (1ml/h step ,input 016 when set the rate from 800 to 1200ml/h)


2. Rate Accuracy within±5% (after correct calibration)


3. Purge Rate 100ml/h---1200ml/h(can be calibrated)


4. Volume Limit 0ml---9999ml   Total Infusion Volume  0---9999.9 ml


5. Alarm Pressure 
   High: 800mmHg±200mmHg(106.7kPa±26.7kPa)
   Medium: 500mmHg±100mmHg(66.7kPa±13.3kPa)
   Low: 300mmHg±100mmHg(40.7kPa±13.3kPa)


6. Alarms             
end of injection, occlusion, door open, bubbles in the tube, wrong setting,
low battery, AC power pulled out etc


7. Power source 100V---240V  50/60Hz


8. Internal rechargeable Li battery volume≥1,600mAh  
   4 hours internal battery backup
 

9. Bubble Detector ultrasonic wave detector, detection sensitivity ≥25μL


10. KVO Speed 1ml/h---5ml/h (1ml/h step)


11. Power Consumption 15VA


12. Operation Environment Temperature  +5----+40 degree
                                            Relative Humidity  20----90%  
                                            Storage Temperature  -30-----+55 degree
                                            Humidity   ≤95%
                                            Atmospheric Pressure  50.10KPa----106.0KPa


13. Weight 1.8kg


14. Dimension 140mm (L)x 157mm (W)x 220mm (H)


15. Infusion set brand Compatible with any brand


16.Forbidden Not support blood Infusion
 

17. Package 1pc per each Carton, 2.8KG

 

Beijing Carejoy Technology Co., Ltd. All rights reserved. E-mail: info@carejoy.com.cn